Accuracy
0-10 m/s 0.3 m/s RMSE
10-40 m/s 3% RMSE
40-60 m/s 5% RMSE
Units of measurement
m/s, km/h, mph, kts, ft/min
Accuracy
0.5 m/s-40 m/s ±3°
40-60 m/s ±5°
Units of measurement
Degrees
Range
-40°C to +70°C with heating
Units of measurement
°C, °F, K
Accuracy
typically ±2% RH across full range
Units of measurement
% RH, g/m3
Accuracy 900-1100 hPa, 25-40°C
Absolute (typically) ±0.4 hPa Relative (typically) ±0.08 hPa
Wavelength sensitivity
300 – 3000 nm
DIN Standard
ISO 9060 Second Class
Units of measurement
W/m2
Operating temperature
-35°C to +70°C
-40°C to +70°C with heating option
Storage temperature
-40°C to +70°C
Construction
UV stabilized thermoplastic
Fittings
Fit to 30mm to 58mm pole or mast
Connector Type
9-way clipper connector
Input voltage
5-30 VDC (10-30 VDC for heated models)
Current spec @ 12 VDC
25 mA continuous mode (std unit)
400 mA total with heating
+10 mA with GPS option
0.7 mA eco-power mode
Weather Station
Specifications
Accuracy
0-10 m/s 0.3 m/s RMSE
10-40 m/s 3% RMSE
40-60 m/s 5% RMSE
Units of measurement
m/s, km/h, mph, kts, ft/min
Accuracy
0.5 m/s-40 m/s ±3°
40-60 m/s ±5°
Units of measurement
Degrees
Range
-40°C to +70°C with heating
Units of measurement
°C, °F, K
Accuracy
typically ±2% RH across full range
Units of measurement
% RH, g/m3
Accuracy 900-1100 hPa, 25-40°C
Absolute (typically) ±0.4 hPa Relative (typically) ±0.08 hPa
Wavelength sensitivity
300 – 3000 nm
DIN Standard
ISO 9060 Second Class
Units of measurement
W/m2
Operating temperature
-35°C to +70°C
-40°C to +70°C with heating option
Storage temperature
-40°C to +70°C
Construction
UV stabilized thermoplastic
Fittings
Fit to 30mm to 58mm pole or mast
Connector Type
9-way clipper connector
Input voltage
5-30 VDC (10-30 VDC for heated models)
Current spec @ 12 VDC
25 mA continuous mode (std unit)
400 mA total with heating
+10 mA with GPS option